FM SERIES PHOTOELECTRIC SENSOR | |||
| Opposed mode: | sn=3m / 30m | |||
| Diffuse mode: | sn=300mm / 380mm | |||
| Retroreflective mode: | sn=5m | |||
| Polarized reflective mode: | sn=2m | |||
| Convergent mode | sn= 16mm / 43mm | |||
| House size: | 53x12x30mm / 39X12X30mm | |||
| FM SERIES PHOTOELECTRIC SENSORS SPECIFICATIONS(DC) | ||||
|
SENSING MODE/ ITEM |
DC | |||
|
OPPOSED MODE |
RETRO REFLECTIVE MODE |
DIFFUSED MODE | ||
|
E |
R | |||
| Sensing Range |
see each mode | |||
| Hysteresis |
- | |||
| Operating Voltage |
10~30v | |||
| Ripple |
< ¡¾ 20% | |||
| Voltage Drop |
- |
<2.0V at 150mA | ||
| Max Load Current |
- |
150mA | ||
| No Load Current |
<25mA | |||
| Min. Load Current |
- |
5mA | ||
| Leakage Current |
- |
<1mA | ||
| Output Configuration |
Bipolar: One current sourcing (PNP) and one current sinking (NPN) open-collector transistor | |||
| Indicators | Red indicator LED on rear or sensor is on when the load is energized | |||
| Adjustments | LIGHT/DARK OPERATE select switch, and 15-turn slotted brass screw GAIN (sensitivity) adjustment potentiometer(clutched at both ends of travel). Both controls are located on rear panel of sensor and protected by a gasketed, clear acrylic cover. | |||
| Transiet protection | yes | |||
| Resverse polarity protection | yes | |||
| Short Circuit Protection | yes | |||
| Over Load current protection | >180mA | |||
| Output response time | 1ms or 0.3ms(High-speed TYPE) | |||
| Construction | Reinforced thermoplastic polyester housing, totally encapsulated, o-ring sealing, acrylic lenses, and stainless screws. | |||
| Environmental rating | IP67 | |||
| Operating Conditions | Temperature: -20 ¡ÆCto +70 ¡ÆC, Maximum relative humidity: 90% at 50OC | |||
| EMC | IEC 60947-5-2, Parts 7.2.6.1. 2. 3 or RFI>3V/m(in 30-1000MHZ), EFT>1KV, ESD>4KV(contact) | |||
| Voltage Withstand Ability | IEC 60947-5-2, Part 8.3.3.4 or 500VDC for one min, between all supply terminals connected together and enclosure | |||
| Insulation Resistance | >20M¥Ø , with 500V DC megger between all supply terminals connected together and enclosure | |||
| Vibration Resistance | IEC 60947-5-2, Part 7.4.2 or 10-55HZ, 1.0mm amplitude in x , y and z directions for 30 min | |||
| Shock Resistance | IEC 60947-5-2, Part 7.4.1 or 30g, 11ms in x , y and z directions for six time each | |||
| FM SERIES PHOTOELECTRIC SENSORS SPECIFICATIONS(AC) | ||||
|
SENSING MODE/ ITEM |
AC | |||
|
OPPOSED MODE |
RETRO REFLECTIVE MODE |
DIFFUSED MODE | ||
|
E |
R | |||
| Sensing Range |
see each mode | |||
| Hysteresis |
- |
|||
| Operating Voltage |
24~240V AC (50/60HZ) | |||
| Output configuration |
SPST MOSFET solid-state relay with either normally closed or normally open contact (light/diark operate selectable; 3-wire hookup | |||
| Voltage Drop |
- |
<10V at 200mA | ||
| Max Load Current |
- |
<200mA | ||
| No Load Current |
25mA |
<1.7mA | ||
| Min. Load Current |
- |
<5mA | ||
| Leakage Current |
- |
<1.7mA | ||
| Transiet protection |
| |||
| Short Circuit Protection | - |
yes | ||
| Over Load current protection | - |
>220mA | ||
| Response Time | 2ms | 8ms | 4ms | 8ms |
| Construction | Reinforced thermoplastic polyester housing, totally encapsulated, o-ring sealing, acrylic lenses, and stainless screws. | |||
| Adjustments | LIGHT/DARK OPERATE select switch, and 15-turn slotted brass screw GAIN (sensitivity) adjustment potentiometers (clutched at both ends of travel). Both controls are located on rear panel of sensor and protected, clear acrylic cover. | |||
| Indicators | Red indicator LED on rear or sensor is on when the load is energized | |||
| Environmental rating | IP67 | |||
| Operating Temperature | Temperature: -20C to +70C, Maximum relative humidity: 90% at 50C | |||
| EMC | IEC 60947-5-2, Parts 7.2.6.1. 2. 3 or RFI>3V/m(in 30-1000MHZ), EFT>1KV, SD>4KV(contact) | |||
| Voltage Withstand Ability | IEC 60947-5-2, Part 8.3.3.4 or 500VDC for one min, between all supply terminals connected together and enclosure | |||
| Insulation Resistance | >20M¥Ø , with 500V DC megger between all supply terminals connected together and enclosure | |||
| Vibration Resistance | IEC 60947-5-2, Part 7.4.2 or 10-55HZ, 1.0mm amplitude in x , y and z directions for 30 min | |||
| Shock Resistance | IEC 60947-5-2, Part 7.4.1 or 30g, 11ms in x , y and z directions for six time each | |||
| FM SERIES PHOTOELECTRIC SENSORS CONNECTION DIAGRAM |
| Receiver: NPN / PNP output wiring diagram (DC) |
__________ __________![]() |
| Emitter wiring diagram (DC) |
_____________ ____________![]() |
| Receiver: wiring diagram (AC) |
____________![]() |
| Emitter wiring diagram (AC) |
_______-_____![]() |
| FM SERIES PHOTOELECTRIC SENSORS DIMENSIONS | |
| DC SENSOR | |
![]() |
![]() |
| AC SENSOR | |
![]() |
![]() |